1.4  Possible Problem Upgrading Firmware on AlphaServer
       4100 Systems for V7.2-EFT3
  If you are using an AlphaServer 4100 system to field test
  OpenVMS Galaxy or Version 7.2-EFT3, you should be aware
  of a possible problem with upgrading the firmware.
  When upgrading from any pre-V5.2 firmware to the AS4_
  G52-59 firmware file, the system may hang or output a
  dump of the "Active Call Frames".
  If this happens, do the following:
  1.  Power-cycle the system.
  2.  Upgrade to Alpha Systems Firmware Update Version 5.2
      in the Version 7.2-EFT3 CD-ROM kit.
  3.  Then upgrade from Alpha Systems Firmware Update
      Version 5.2 to AS4_G52-59.
      Note that the AS4_G52-59 firmware file is in the
      OpenVMS Galaxy firmware kit (GALAXY_FIRM_
      072.KIT) on the OpenVMS Alpha Version 7.2-EFT3
      CD-ROM 2.
  If you have any questions with this procedure, please get in
  touch with your V7.2-EFT3 engineering directed field test
  site contact.  The problem will be corrected in the final release
  of OpenVMS Alpha Version 7.2.