MSA_UTIL_HELP.HLB  —  SET  GLOBALS  Qualifiers

1    /EXPAND_PRIORITY

                Specifies the expansion priority for the RAID Volumes.

                Format:
                        /EXPAND_PRIORITY=(LOW | MEDIUM | HIGH)

                Description:

                EXPAND_PRIORITY=HIGH-the expand priority. Used when
                expanding an array to set the priority of array
                expansions in relation to input/output operations.
                See below for detailed information about these
                settings.

2    /READ_CACHE

                Specifies the percentage of cache to be used on READ
                commands.

                Format:
                        /READ_CACHE=(AUTOMATIC | #percent)

                Description:

                READ_CACHE=50-the read cache. This value must be
                between 0 and 100.

3    /REBUILD_PRIORITY

                Specifies the Rebuild priority of the RAID Volume.

                Format:
                        /REBUILD_P=(LOW | MEDIUM | HIGH)

                Description:

                REBUILD_PRIORITY=HIGH-the rebuild priority. Used
                when rebuilding an array to set the priority of an
                array rebuild in relation to input/output operations.
                Low-expansion or rebuild takes place only when the
                array controller is not busy handling normal I/O
                requests. This setting has minimal effect on normal
                I/O operations. However, there is an increased risk
                that data will be lost if another physical drive
                fails while the rebuild is in progress.

4    /WRITE_CACHE

                Specifies the percentage of cache to be used on WRITE
                commands.

                Format:
                        /WRITE_CACHE=(AUTOMATIC | #percent)

                Description:

                WRITE_CACHE=50-the write cache. This value must be
                between 0 and 100.

5    /SYSTEM_NAME

                Specifies the name to be assigned for the controller.

                Note: This qualifier is not supported for Smart Arrays.

                Format:
                        /SYSTEM_NAME=(name)

                Description:

                SYSTEM_NAME="XXX"-the system name, where XXX represents
                any user defined phrase, up to 20 alphanumeric characters.

6    /VERBOSE

                Provides logging that can be interpreted by engineering.
Close Help