SHOW CONTROLLER displays the specified controller's
information if the controller name is provided. If
the controller name is not provided, then information
of all the connected controllers is displayed.
The SHOW CONTROLLER command is synonymous to the
SHOW ADAPTER command.
Note: If the context is set to a specific controller
and the controller name is not provided, then
SHOW CONTROLLER displays information pertaining
only to the controller to which the context is
set.
Format:
SHOW CONTROLLER (Controller_name:) / <qualifiers>
1 – Parameters
Controller_name:
2 – Qualifiers
2.1 /BUS
Displays the Bus number of the controller.
2.2 /BRIEF
Displays limited information of the controller.
2.3 /DEFAULT
Displays information of the default controller.
2.4 /NODEFAULT
Displays information of all the controllers.
2.5 /FULL
Displays extensive information of the controller.
2.6 /REVISION
Displays the firmware version of the controller along
with the default information for the controller.
2.7 /SUBSYSTEM
Displays the Subsystem ID of the controller.
2.8 /VERBOSE
Provides logging that can be interpreted by engineering.
3 – Examples
MSA> SHOW CONTROLLER
A default controller is not set. All matching controllers
displayed
Controller: _$1$GGA201:
MSA1000 (c) COMPAQ P56350B9IN2021 Software 4.42
Controller Identifer: 201
NODE_ID = 500805f3-0001b660
SCSI_VERSION = SCSI-3
Supported Redundancy Mode: Active/Standby
Current Redundancy mode: Active/Standby
Current Role: Standby
Device Port SCSI address 6
Host Port_1:
REPORTED PORT_ID = 500805f3-0001b669
PORT_1_TOPOLOGY = Not available to this program
Cache:
102 megabyte read cache 154 megabyte write cache
Cache is GOOD, and Cache is enabled.
No unflushed data in cache.
Battery:
Battery is fully charged.
Controller: _$1$GGA300:
MSA CONTROLLER (c) HP P56350GX3QN152 Software 6.72
Controller Identifier: 300
NODE_ID = 500508b3-00905ed0
SCSI_VERSION = SCSI-3
Supported Redundancy Mode: Asym Active/Active Active/Standby
Current Redundancy mode: Asymmetrical Active/Active
Current Role: Active
Device Port SCSI address 7
Host Port_1:
REPORTED PORT_ID = 500508b3-00905ed1
PORT_1_TOPOLOGY = Not available to this program
Cache:
128 megabyte read cache 128 megabyte write cache
Cache is GOOD, and Cache is enabled.
No unflushed data in cache.
Battery:
Battery is fully charged.
Controller: _$1$GGA301:
MSA CONTROLLER (c) HP P56350GX3QN0FS Software 6.72
Controller Identifier: 301
NODE_ID = 500508b3-00905ed0
SCSI_VERSION = SCSI-3
Supported Redundancy Mode: Asym Active/Active Active/Standby
Current Redundancy mode: Asymmetrical Active/Active
Current Role: Active
Device Port SCSI address 6
Host Port_1:
REPORTED PORT_ID = 500508b3-00905ed9
PORT_1_TOPOLOGY = Not available to this program
Cache:
128 megabyte read cache 128 megabyte write cache
Cache is GOOD, and Cache is enabled.
No unflushed data in cache.
Battery:
Battery is fully charged.
Controller: _$1$GGA1002:
MSA1000 (c) COMPAQ P56350A9IMN06M Software 4.42
Controller Identifier: 1002
NODE_ID = 500805f3-0001b660
SCSI_VERSION = SCSI-3
Supported Redundancy Mode: Active/Standby
Current Redundancy mode: Active/Standby
Current Role: Active
Device Port SCSI address 7
Host Port_1:
REPORTED PORT_ID = 500805f3-0001b661
PORT_1_TOPOLOGY = Not available to this program
Cache:
102 megabyte read cache 154 megabyte write cache
Cache is GOOD, and Cache is enabled.
No unflushed data in cache.
Battery:
Battery is fully charged.
Adapter: _PKD0:
SA6400 (c) HP P57820FDAPHJE7 Software 1.92
SCSI_VERSION = X3.131:1994 (SCSI-2)
Not currently Redundant
Current Role: Active
(No redundant controller installed)
Cache:
128 megabyte read/write cache
Cache is not configured, and Cache is disabled.
No unflushed data in cache.
Battery:
Battery is not fully charged.
Adapter: _PKE0:
SA6400 EM (c) HP P577C0EDAPH3JK Software 1.92
SCSI_VERSION = X3.131:1994 (SCSI-2)
Not currently Redundant
Current Role: Active
(No redundant controller installed)
Cache:
128 megabyte read/write cache
Cache is not configured, and Cache is disabled.
No unflushed data in cache.
Battery:
Battery is not fully charged.