1 /CACHE
/CACHE /NOCACHE (default) Enables or disables write caching to the physical disk. Write caching to the physical disk is set to off by default.
2 /DISK
/DISK=sas_id(,...) This qualifier is required. Specifies the SAS ID of the physical disk to be added to the IR volume set. (The SAS ID is the ID shown when you enter the SAS command SHOW DISK.) Enclose multiple SAS IDs in parentheses. The effective size of the RAID volume is automatically determined and set to the maximum size available. The firmware supports disks of varying sizes; however, the excess space of a larger disk or disks is unusable. Volume expansion is not supported; once a volume is created, its size cannot be increased. A physical disk must be dismounted in OpenVMS before it can be added to the IR volume set.
3 /RAID
/RAID=(0 | 1 | 10) This qualifier is required. Specifies the RAID level of the IR volume set. RAID levels are the following: RAID Level Description RAID 0 Integrated Striping RAID 1 Integrated Mirroring RAID 10 Integrated Mirroring Enhanced NOTE OpenVMS Version 8.3 supports RAID 1 (Integrated Mirroring).
4 /SPARE
/SPARE=sas_id Specifies the SAS ID of the physical disk to be added as the Global Hot Spare disk. This qualifier is required when specifying a Global Hot Spare disk for a RAID 1 configuration. You can configure one Global Hot Spare disk per controller. The spare drive can be shared between two RAID 1 IR volume sets per controller. The size of the disk specified as /SPARE should be greater than or equal to the size of at least one of the physical disks on the IR volume.
5 /SYNCH
/SYNCH /NOSYNCH (default) This qualifier applies only to RAID 1 IR volumes. Specifies the use of high-priority or low-priority resynchronization. High- priority resynchronization is set to OFF by default.
6 /UNSAFE
Overrides the restriction that limits OpenVMS support to RAID 1 only.